Last Modified: 11-29-2007 1.6 C
Service Category: Engine/Hybrid System Section: Engine Control
Model Year: 2008 Model: Sequoia Doc ID: RM000000TB302WX
Title: 3UR-FE ENGINE CONTROL: SFI SYSTEM: CAUTION / NOTICE / HINT (2008 Sequoia)

DTC

P0128

Coolant Thermostat (Coolant Temperature Below Thermostat Regulating Temperature)

CAUTION / NOTICE / HINT

DESCRIPTION

This DTC is stored when the Engine Coolant Temperature (ECT) does not reach 75°C (167°F) despite sufficient engine warm-up time having elapsed.

DTC No.

DTC Detection Condition

Trouble Area

P0128

Conditions (a), (b) and (c) met for 5 seconds (2 trip detection logic):

(a) Cold start

(b) Engine warmed up

(c) ECT less than 75°C (167°F)

  • Thermostat
  • Cooling system
  • ECT sensor
  • ECM

MONITOR DESCRIPTION



The ECM estimates the ECT based on the starting temperature, engine loads, and engine speeds. The ECM then compares the estimated temperature with the actual ECT. When the estimated ECT reaches 75°C (167°F), the ECM checks the actual ECT. If the actual ECT is less than 75°C (167°F), the ECM interprets this as a malfunction in the thermostat or the engine cooling system and stores the DTC.

MONITOR STRATEGY

Related DTCs

P0128: Coolant Thermostat

Required Sensors/Components (Main)

Thermostat

Required Sensors/Components (Related)

Engine Coolant Temperature (ECT) sensor, Intake Air Temperature (IAT) sensor, Vehicle speed sensor

Frequency of Operation

Once per driving cycle

Duration

900 seconds

MIL Operation

2 driving cycles

Sequence of Operation

None

TYPICAL ENABLING CONDITIONS

Monitor runs whenever following DTCs not present

P0010 , P0020 (VVT OCV)

P0011 (VVT System 1 - Advance)

P0012 (VVT System 1 - Retard)

P0021 (VVT System 2 - Advance)

P0022 (VVT System 2 - Retard)

P0031, P0032, P0051, P0052 (A/F Sensor Heater - Sensor 1)

P0102 - P0103 (MAF meter)

P0110 - P0113 (IAT sensor)

P0115 - P0118 (ECT sensor)

P0125 (Insufficient ECT for Closed Loop)

P0171, P0172 (Fuel system)

P0300 - P0308 (Misfire)

P0335 (CKP sensor)

P0340 - P0346 (VVT sensor 1, 2)

P0351 - P0358 (Igniter)

P0500 (VSS)

P2196, P2198 (A/F sensor - rationality)

P2237, P2240 (A/F sensor - open)

P2A00, P2A03 (A/F sensor - slow response)

Battery voltage

11 V or more

Either of following conditions 1 or 2 met:

-

1. All of following conditions met:

-

  • ECT at engine start - IAT at engine start

-15 to 7°C (-27 to 12.6°F)

  • ECT at engine start

-10 to 56°C (14 to 133°F)

  • IAT at engine start

-10 to 56°C (14 to 133°F)

2. All of following conditions met:

-

  • ECT at engine start - IAT at engine start

More than 7°C (12.6 °F)

  • ECT at engine start

56°C (133°F) or less

  • IAT at engine start

-10°C (14°F) or more

Accumulated time at 128 km/h (80 mph) or more of vehicle speed

Less than 20 seconds

TYPICAL MALFUNCTION THRESHOLDS

Duration that both of following conditions (a) and (b) met

5 seconds or more

(a) Estimated ECT

75°C (167°F) or more

(b) ECT sensor output

Below 75°C (167°F)

INSPECTION PROCEDURE

HINT:

  • This DTC relates to the thermostat.
  • Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE

1.

CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0128)

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

(e) Read DTCs.

Result

Result

Proceed to

P0128 is output

A

P0128 and other DTCs are output

B

HINT:

If any DTCs other than P0128 are output, troubleshoot those DTCs first.

A

2.

CHECK COOLING SYSTEM

(a) Check for defects in the cooling system that might cause the system to be too cold, such as abnormal radiator fan operation or any modifications.

OK

3.

INSPECT THERMOSTAT

(a) Remove the thermostat 3UR-FE COOLING: THERMOSTAT: REMOVAL (2008 Sequoia) .

(b) Measure the valve opening temperature of the thermostat.

Standard opening temperature:

80 to 84°C (176 to 183°F)

HINT:

In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

(c) Reinstall the thermostat 3UR-FE COOLING: THERMOSTAT: INSTALLATION (2008 Sequoia) .

OK